Legrand MCB

Our range of products include legrand rx 3 32a fp mcb, legrand rx 3 4a tp mcb, legrand dx 3 40-63a fp mcb, legrand rx 3 4a sp mcb, legrand rx 3 32a tp mcb and legrand rx 3 4a fp mcb.

Legrand RX 3 32A FP MCB

Request Callback

₹ 2000 / Piece Get Latest Price

PhaseThree Phase
Tripping CurveC
Number of Poles3 Pole
DIN Rail Mount TypeYes
Current32A
BrandLegrand
ModelRX 3
Rated Voltage400V
Voltage TypeAC
  • Breaking capacity 6000A according to IEC 60898 - 1 standard for household installations. Tripping threshold in case of short - circuit between 189A and 315A (B curve between 3 In and 5 In)
  • Can be supplied either by copper cable, prong busbar (top side or bottom side), fork busbar (bottom side) or Legrand HX3 plug busbar (top side).
  • Protected against solid bodies larger than 12,5mm ("fingerproof") : IP20 according to IEC/EN 60529 standard. Maximum level of limitation of the let through energy (energy limitation class 3 according to IEC 60898 - 1 standard).
  • Can be equipped with Legrand DX3 auxiliaries, RCD add-on modules and accessories. Can be connected to aluminium cable with terminal accessory n° 4 063 10.
  • This device complies with substance-restriction requirements and has been designed in an environmentally conscious process.

Legrand RX 3 4A TP MCB

Request Callback

₹ 2000 / Piece Get Latest Price

PhaseThree Phase
Tripping CurveC
Number of Poles3 Pole
DIN Rail Mount TypeYes
Voltage TypeAC
BrandLegrand
ModelRX 3
Current4A
Rated Voltage400V
Release CharacteristicB
  • Breaking capacity 6000A according to IEC 60898 - 1 standard for household installations. Tripping threshold in case of short - circuit between 189A and 315A (B curve between 3 In and 5 In)
  • Can be supplied either by copper cable, prong busbar (top side or bottom side), fork busbar (bottom side) or Legrand HX3 plug busbar (top side).
  • Protected against solid bodies larger than 12,5mm ("fingerproof") : IP20 according to IEC/EN 60529 standard. Maximum level of limitation of the let through energy (energy limitation class 3 according to IEC 60898 - 1 standard).
  • Can be equipped with Legrand DX3 auxiliaries, RCD add-on modules and accessories. Can be connected to aluminium cable with terminal accessory n° 4 063 10.
  • This device complies with substance-restriction requirements and has been designed in an environmentally conscious process.

Legrand DX 3 40-63A FP MCB

Request Callback

Get Latest Price

PhaseThree Phase
Tripping CurveC
Number of Poles4 Pole
DIN Rail Mount TypeYes
Current40A
BrandLegrand
ModelDX 3
Rated Voltage400V
Frequency50Hz
  • Breaking capacity 6000A according to IEC 60898 - 1 standard for household installations. Tripping threshold in case of short - circuit between 189A and 315A (B curve between 3 In and 5 In)
  • Can be supplied either by copper cable, prong busbar (top side or bottom side), fork busbar (bottom side) or Legrand HX3 plug busbar (top side).
  • Protected against solid bodies larger than 12,5mm ("fingerproof") : IP20 according to IEC/EN 60529 standard. Maximum level of limitation of the let through energy (energy limitation class 3 according to IEC 60898 - 1 standard).
  • Can be equipped with Legrand DX3 auxiliaries, RCD add-on modules and accessories. Can be connected to aluminium cable with terminal accessory n° 4 063 10.
  • This device complies with substance-restriction requirements and has been designed in an environmentally conscious process.

Legrand RX 3 4A SP MCB

Request Callback

Get Latest Price

Number Of Poles1 pole
PhaseSingle Phase
Tripping CurveC
Current4A
BrandLegrand
ModelRX 3
Rated Voltage400 V
Voltage TypeAC
Frequency50Hz
Pollution Degree2
Release Characteristic2
  • Breaking capacity 6000A according to IEC 60898 - 1 standard for household installations. Tripping threshold in case of short - circuit between 189A and 315A (B curve between 3 In and 5 In)
  • Can be supplied either by copper cable, prong busbar (top side or bottom side), fork busbar (bottom side) or Legrand HX3 plug busbar (top side).
  • Protected against solid bodies larger than 12,5mm ("fingerproof") : IP20 according to IEC/EN 60529 standard. Maximum level of limitation of the let through energy (energy limitation class 3 according to IEC 60898 - 1 standard).
  • Can be equipped with Legrand DX3 auxiliaries, RCD add-on modules and accessories. Can be connected to aluminium cable with terminal accessory n° 4 063 10.
  • This device complies with substance-restriction requirements and has been designed in an environmentally conscious process.

Legrand RX 3 32A TP MCB

Request Callback

₹ 2000 / Piece Get Latest Price

PhaseThree Phase
Tripping CurveC
Number of Poles3 Pole
DIN Rail Mount TypeYes
Current32A
BrandLegrand
ModelRX 3
Release CharacteristicB
Voltage TypeAC
Rated Voltage400V
  • Breaking capacity 6000A according to IEC 60898 - 1 standard for household installations. Tripping threshold in case of short - circuit between 189A and 315A (B curve between 3 In and 5 In)
  • Can be supplied either by copper cable, prong busbar (top side or bottom side), fork busbar (bottom side) or Legrand HX3 plug busbar (top side).
  • Protected against solid bodies larger than 12,5mm ("fingerproof") : IP20 according to IEC/EN 60529 standard. Maximum level of limitation of the let through energy (energy limitation class 3 according to IEC 60898 - 1 standard).
  • Can be equipped with Legrand DX3 auxiliaries, RCD add-on modules and accessories. Can be connected to aluminium cable with terminal accessory n° 4 063 10.
  • This device complies with substance-restriction requirements and has been designed in an environmentally conscious process.

Legrand RX 3 4A FP MCB

Request Callback

₹ 2000 / Piece Get Latest Price

PhaseTwo Phase
Tripping CurveC
Number of Poles2 Pole
DIN Rail Mount TypeYes
Current4A
Rated Voltage400V
BrandLegrand
ModelRX 3
Release CharacteristicB
  • Breaking capacity 6000A according to IEC 60898 - 1 standard for household installations. Tripping threshold in case of short - circuit between 189A and 315A (B curve between 3 In and 5 In)
  • Can be supplied either by copper cable, prong busbar (top side or bottom side), fork busbar (bottom side) or Legrand HX3 plug busbar (top side).
  • Protected against solid bodies larger than 12,5mm ("fingerproof") : IP20 according to IEC/EN 60529 standard. Maximum level of limitation of the let through energy (energy limitation class 3 according to IEC 60898 - 1 standard).
  • Can be equipped with Legrand DX3 auxiliaries, RCD add-on modules and accessories. Can be connected to aluminium cable with terminal accessory n° 4 063 10.
  • This device complies with substance-restriction requirements and has been designed in an environmentally conscious process.

Legrand DX 3 4A TP MCB

Request Callback

₹ 2000 / Piece Get Latest Price

PhaseThree Phase
Tripping CurveC
Number of Poles3 Pole
DIN Rail Mount TypeYes
Current4A
BrandLegrand
Rated Voltage400V
Voltage TypeAC
  • Breaking capacity 6000A according to IEC 60898 - 1 standard for household installations. Tripping threshold in case of short - circuit between 189A and 315A (B curve between 3 In and 5 In)
  • Can be supplied either by copper cable, prong busbar (top side or bottom side), fork busbar (bottom side) or Legrand HX3 plug busbar (top side).
  • Protected against solid bodies larger than 12,5mm ("fingerproof") : IP20 according to IEC/EN 60529 standard. Maximum level of limitation of the let through energy (energy limitation class 3 according to IEC 60898 - 1 standard).
  • Can be equipped with Legrand DX3 auxiliaries, RCD add-on modules and accessories. Can be connected to aluminium cable with terminal accessory n° 4 063 10.
  • This device complies with substance-restriction requirements and has been designed in an environmentally conscious process.

Legrand DX 3 32A DP MCB

Request Callback

₹ 2000 / Piece Get Latest Price

PhaseThree Phase
Tripping CurveD
Number of Poles2 Pole
DIN Rail Mount TypeYes
Item Code407512
Current32A
BrandLegrand
Rated Voltage400 V
Voltage TypeAC
Frequency50Hz
Pollution Degree2
Release Characteristic2
  • Breaking capacity 6000A according to IEC 60898 - 1 standard for household installations. Tripping threshold in case of short - circuit between 96A and 160A (B curve between 3 In and 5 In)
  • Can be supplied either by copper cable, prong busbar (top side or bottom side), fork busbar (bottom side) or Legrand HX3 plug busbar (top side).
  • Protected against solid bodies larger than 12,5mm ("fingerproof") : IP20 according to IEC/EN 60529 standard. Maximum level of limitation of the let through energy (energy limitation class 3 according to IEC 60898 - 1 standard).
  • Can be equipped with Legrand DX3 auxiliaries, RCD add-on modules and accessories. Can be connected to aluminium cable with terminal accessory n° 4 063 10.
  • This device complies with substance-restriction requirements and has been designed in an environmentally conscious process.

Legrand DX 3 32A TP MCB

Request Callback

₹ 2000 / Piece Get Latest Price

PhaseThree Phase
Tripping CurveC
Number of Poles3 Pole
DIN Rail Mount TypeYes
Item Code409784
Current32A
BrandLegrand
ModelDX 3
Rated Voltage400V
Frequency50 Hz
  • Breaking capacity 6000A according to IEC 60898 - 1 standard for household installations. Tripping threshold in case of short - circuit between 189A and 315A (B curve between 3 In and 5 In)
  • Can be supplied either by copper cable, prong busbar (top side or bottom side), fork busbar (bottom side) or Legrand HX3 plug busbar (top side).
  • Protected against solid bodies larger than 12,5mm ("fingerproof") : IP20 according to IEC/EN 60529 standard. Maximum level of limitation of the let through energy (energy limitation class 3 according to IEC 60898 - 1 standard).
  • Can be equipped with Legrand DX3 auxiliaries, RCD add-on modules and accessories. Can be connected to aluminium cable with terminal accessory n° 4 063 10.
  • This device complies with substance-restriction requirements and has been designed in an environmentally conscious process.

Legrand RX 3 63A TP MCB

Request Callback

₹ 2000 / Piece Get Latest Price

PhaseSingle Phase
Tripping CurveC
Number of Poles3 Pole
DIN Rail Mount TypeYes
Current63A
BrandLegrand
ModelRX 3
Rated Voltage400V
Voltage TypeAC
  • Breaking capacity 6000A according to IEC 60898 - 1 standard for household installations. Tripping threshold in case of short - circuit between 189A and 315A (B curve between 3 In and 5 In)
  • Can be supplied either by copper cable, prong busbar (top side or bottom side), fork busbar (bottom side) or Legrand HX3 plug busbar (top side).
  • Protected against solid bodies larger than 12,5mm ("fingerproof") : IP20 according to IEC/EN 60529 standard. Maximum level of limitation of the let through energy (energy limitation class 3 according to IEC 60898 - 1 standard).
  • Can be equipped with Legrand DX3 auxiliaries, RCD add-on modules and accessories. Can be connected to aluminium cable with terminal accessory n° 4 063 10.
  • This device complies with substance-restriction requirements and has been designed in an environmentally conscious process.

Legrand DX 3 4A SP MCB

Request Callback

Get Latest Price

PhaseTwo Phase
Tripping CurveC
Number of Poles3 Pole
DIN Rail Mount TypeYes
Current4A
BrandLegrand
ModelDX 3
Rated Voltage400V
Voltage TypeAC
We are engaged in offering this product to our clients. Our range of all products is widely appreciated by our clients.

Legrand RX 3 6A DP MCB

Request Callback

Get Latest Price

PhaseTwo Phase
Tripping CurveC
Rated Current6A
Number of Poles2 Pole
DIN Rail Mount TypeYes
BrandLegrand
ModelRX 3
Rated Voltage400V
Voltage TypeAC
Release CharacteristicB
  • Breaking capacity 6000A according to IEC 60898 - 1 standard for household installations. Tripping threshold in case of short - circuit between 189A and 315A (B curve between 3 In and 5 In)
  • Can be supplied either by copper cable, prong busbar (top side or bottom side), fork busbar (bottom side) or Legrand HX3 plug busbar (top side).
  • Protected against solid bodies larger than 12,5mm ("fingerproof") : IP20 according to IEC/EN 60529 standard. Maximum level of limitation of the let through energy (energy limitation class 3 according to IEC 60898 - 1 standard).
  • Can be equipped with Legrand DX3 auxiliaries, RCD add-on modules and accessories. Can be connected to aluminium cable with terminal accessory n° 4 063 10.
  • This device complies with substance-restriction requirements and has been designed in an environmentally conscious process.

Legrand DX 3 4A DP MCB

Request Callback

Get Latest Price

PhaseTwo Phase
Tripping CurveC
Rated Current4A
Voltage400 v
Number of Poles2 Pole
DIN Rail Mount TypeYes
Body MaterialPVC
Temperature70 degree c
We are engaged in offering this product to our clients. Our range of all products is widely appreciated by our clients.

Legrand RX 3 4A DP MCB

Request Callback

Get Latest Price

PhaseSingle Phase
Tripping CurveC
Number of Poles1 Pole
DIN Rail Mount TypeYes
Current4A
BrandLegrand
ModelRX 3
Rated Voltage400V
Voltage TypeAC
We are engaged in offering this product to our clients. Our range of all products is widely appreciated by our clients.

Legrand RX 3 40A SP MCB

Request Callback

Get Latest Price

PhaseTwo Phase
Tripping CurveC
Number of Poles2 Pole
DIN Rail Mount TypeYes
Current40A
BrandLegrand
ModelRX 3
Voltage TypeAC
Rated Voltage400V
We are engaged in offering this product to our clients. Our range of all products is widely appreciated by our clients.

Legrand 4A DP MCB

Request Callback

Get Latest Price

PhaseTwo Phase
Tripping CurveC
Number of Poles3 Pole
Mounting TypeDIN Rail
Body MaterialPVC
Temperature70 degree c
Voltage440V AC
BrandLegrand
ModelDP
  • Breaking Capacity: 10 Ka
  • Category: Mcbs & Dbs
  • Current Rating: 4 Amps
  • No. Of Poles: Dp
  • Searchfilter: Switchgears

Legrand DX 3 6-32A SP MCB

Request Callback

Get Latest Price

PhaseThree Phase
Tripping CurveD
Number of Poles3 Pole
DIN Rail Mount TypeYes
Item Code407512
BrandLegrand
ModelDX 3 6-32A
Depth44 mm
Release CharacteristicB
Voltage TypeAC
Rated Voltage400V
  • Breaking capacity 6000A according to IEC 60898 - 1 standard for household installations. Tripping threshold in case of short - circuit between 96A and 160A (B curve between 3 In and 5 In)
  • Can be supplied either by copper cable, prong busbar (top side or bottom side), fork busbar (bottom side) or Legrand HX3 plug busbar (top side).
  • Protected against solid bodies larger than 12,5mm ("fingerproof") : IP20 according to IEC/EN 60529 standard. Maximum level of limitation of the let through energy (energy limitation class 3 according to IEC 60898 - 1 standard).
  • Can be equipped with Legrand DX3 auxiliaries, RCD add-on modules and accessories. Can be connected to aluminium cable with terminal accessory n° 4 063 10.
  • This device complies with substance-restriction requirements and has been designed in an environmentally conscious process.

Legrand RX 3 6A SP MCB

Request Callback

Get Latest Price

PhaseThree Phase
Tripping CurveC
Rated Current6A
Number of Poles3 Pole
DIN Rail Mount TypeYes
BrandLegrand
ModelRX 3
Rated Voltage400V
Voltage TypeAC
Release CharacteristicB
We are engaged in offering this product to our clients. Our range of all products is widely appreciated by our clients.